What is the Difference Between Open Tubular and Packed Columns?

🆚 Go to Comparative Table 🆚

The main difference between open tubular and packed columns lies in their structure, sample capacity, and separation efficiency. Here are the key differences:

  • Structure: Open tubular columns, also known as capillary columns, have an internal diameter of about a few tenths of a millimeter and are typically made of glass, stainless steel, copper, or aluminum. Packed columns, on the other hand, are constructed from the same materials but have larger internal diameters, ranging from 2 to 4 mm.
  • Sample Capacity: Packed columns can handle larger samples due to their larger diameter, while open tubular columns require a smaller sample size, typically less than 10–2 μL.
  • Separation Efficiency: Open tubular columns have high resolution, while packed columns have low resolution. Capillary columns can separate more complex mixtures, but packed columns can handle larger samples.

There are two major types of open tubular columns: wall-coated open tubular (WCOT) and support-coated open tubular (SCOT). In WCOT, a thin layer of stationary phase is coated on the capillary's inner wall, while in SCOT, a porous solid support is used, such as alumina or silica.

In summary, open tubular columns are suitable for separating complex mixtures with smaller sample sizes, while packed columns can handle larger samples but may have lower separation efficiency.

Comparative Table: Open Tubular vs Packed Columns

The main difference between open tubular and packed columns lies in their sample size requirements and efficiency. Here is a comparison of the two types of columns:

Open Tubular Columns Packed Columns
Require a smaller amount of sample Require a larger amount of sample
Generally have a lower surface area for interactions between analytes and the stationary phase Have a larger surface area for interactions between analytes and the stationary phase
Can achieve higher theoretical plate counts (150,000 to 500,000) Theoretical plate count is limited, with packed columns rarely exceeding 15,000 plates
Wall-coated open tubular (WCOT) and support-coated open tubular (SCOT) are common types A porous solid support, such as alumina, silica gel, or molecular sieves, are used in packed columns

Open tubular columns are commonly used in gas chromatography, while packed columns are used in both gas and liquid chromatography. The choice between open tubular and packed columns depends on the specific requirements of the separation process, such as the desired efficiency, sample size, and type of analytes being separated.