What is the Difference Between Bubble Point and Diffusion Test?

🆚 Go to Comparative Table 🆚

The Bubble Point and Diffusion Test are both integrity tests used to assess the effectiveness of filters, but they use different methods and measurements. Here are the key differences between the two tests:

Bubble Point Test:

  1. Measures the force in gas pressure required to overcome capillary forces and provide an assessment of pore size.
  2. Applies an increasing pressure of air on the upstream side of the filter while monitoring the pressure and flow rate.
  3. Based on the principle of capillary action and surface tension.
  4. Most widely used non-destructive integrity test.

Diffusion Test:

  1. Measures gas flow across the wet membrane at a pressure below the bubble point.
  2. Applies a constant pressure of air on the upstream side of a filter saturated with liquid.
  3. The effectiveness of the test depends on the downstream gas flow rate.
  4. Also known as "forward flow".

Both tests are used to evaluate filter integrity, but they rely on different principles and test conditions. The Bubble Point Test focuses on measuring pressure to determine pore size, while the Diffusion Test measures gas flow across the membrane at a constant pressure. The choice of test depends on factors such as filter type, system size, and desired accuracy.

Comparative Table: Bubble Point vs Diffusion Test

The Bubble Point Test and the Diffusion Test are two different methods used for non-destructive filter integrity testing. Here is a table summarizing the differences between the two tests:

Parameter Bubble Point Test Diffusion Test
Purpose Determine the maximum pore size and pore size distribution of a membrane. Diagnostic and drug susceptibility testing in microbiology.
Method Applies an increasing pressure of air on the upstream side of the filter while monitoring for the first bubble of vapor formation. Applies a constant pressure of air on the upstream side of a filter saturated with liquid, monitoring the flow rate.
Risk The larger the filter system, the higher the risk that a passing diffusion rate could mask a minor breach in the filter membrane. The accuracy of the true bubble point is compromised as the filter system becomes larger.
Suitable for Both hydrophilic and hydrophobic filters. Hydrophilic filters.
Pressure Requires a specific pressure range (e.g., 75-80% of the bubble point). Requires a specific pressure range (e.g., 75-80% of the bubble point).
Test Configuration Wetted with suitable solvent (e.g., water for hydrophilic filters). Wetted with suitable solvent (e.g., water for hydrophilic filters).

Both tests are used to evaluate filter integrity, but they serve different purposes and have different risks associated with them.